648
Writing/reading data to/from refresh devices by specifying a
station number
*2
( MELSEC-Q/L Programming Manual (Common
Instruction))
B
*11 --- ---
High-speed interrupt function
*1*7
---
Version 1.98C or
later
×
Data logging function
*7
( QnUDVCPU/LCPU User's
Manual (Data Logging Function))
---
Version 1.98C or
later
×
IP packet transfer function (for CC-Link IE Controller Network)
( QnUCPU User's Manual (Communication via Built-in
Ethernet Port))
*2*6
"14022" or later
Version 1.98C or
later
×
Use of file registers in communication using the A-compatible
1E frame (MC protocol) through built-in Ethernet port
( QnUCPU User's Manual (Communication via Built-in
Ethernet Port))
*9
--- ---
Increase in the number of routing parameters
( MELSEC-Q/L Programming Manual (Common
Instruction))
*2
*10
Latch clear by using the special relay and special register
areas
*1*2
"15043" or later
(QnUDVCPU
only)
Predefined protocol function "15103" or later 1.501X or later ×
Reading/writing device data from/to the CPU module on
another station by specifying an IP address ( QnUCPU
User's Manual (Communication via Built-in Ethernet Port))
"16043" or later 1.513K or later ---
iQ Sensor Solution function (data backup/restoration only) for
AnyWireASLINK and CC-Link ( iQ Sensor Solution
Reference Manual)
*2
"17012" or later 1.530C or later ---
iQ Sensor Solution function (data backup/restoration only) for
CC-Link IE Field Network ( iQ Sensor Solution
Reference Manual)
*2
"17052" or later
×---
MELSOFT connection extended setting ( QnUCPU
User’s Manual (Communication via Built-in Ethernet Port))
*2
1.535H or later ×
CPU module data backup/restoration function
*1*7
"17103" or later --- ---
Upper limit value setting for the number of backup data (CPU
module data backup/restoration function)
*1*7
"18052" or later --- ---
Retrying the automatic backup (CPU module data
backup/restoration function)
*1*7
iQ Sensor Solution function (automatic detection of connected
device, system configuration check, communication setting
reflection, sensor parameter read/write, monitoring, and data
backup/restoration) for built-in Ethernet ( iQ Sensor
Solution Reference Manual)
*2
"18072" or later 1.550Y or later ---
CC-Link IE Field Network Basic function ( CC-Link IE
Field Network Basic Reference Manual)
*7
"18112" or later
1.555D or later ×
SLMP frame send instruction ( QnUCPU User's Manual
(Communication via Built-in Ethernet Port))
*2
--- ---
Function
Function
version
Serial number
(first 5 digits)
Programming tool version
GX Works2 GX Developer