132
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
Restrictions
The error "Continuous path control not possible" (error code: 1A1EH to 1A20H) will occur and the operation cannot start if
"continuous positioning control" or "continuous path control" is set in "[Da.1] Operation pattern".
"Position-speed switching control" cannot be set in "[Da.2] Control method" of the positioning data when "continuous path
control" has been set in "[Da.1] Operation pattern" of the immediately prior positioning data. (For example, if the operation
pattern of positioning data No. 1 is "continuous path control", "position-speed switching control" cannot be set in positioning
data No. 2.) The error "Continuous path control not possible" (error code: 1A1EH to 1A20H) will occur and the machine will
carry out a deceleration stop if this type of setting is carried out.
The software stroke limit range is only checked during speed control if the "1: Update current feed value" is set in "[Pr.21]
Current feed value during speed control". The software stroke limit range is not checked when the control unit is set to
"degree".
The error "Software stroke limit +" (error code: 1993H) or "Software stroke limit -" (error code: 1995H) will occur and the
operation cannot start if the start point address or end point address for position control exceeds the software stroke limit
range.
Deceleration stop will be carried out if the position-speed switching signal is not input before the machine is moved by a
specified movement amount. When the position-speed switching signal is input during automatic deceleration by
positioning control, acceleration is carried out again to the command speed to continue speed control. When the position-
speed switching signal is input during deceleration to a stop with the stop signal, the control is switched to the speed control
to stop the machine. Restart is carried out by speed control using the restart command.
The warning "Speed limit value over" (warning code: 0991H) will occur and control is continued by "[Pr.8] Speed limit value"
if a new speed exceeds "[Pr.8] Speed limit value" at the time of change of the command speed.
If the value set in "[Da.6] Positioning address/movement amount" is negative, the error "Outside address range" (error
code: 1A30H, 1A31H) will occur.
Set WITH mode in the output timing at M code use. The M code will not be output, and the M code ON signal will not turn
ON if the AFTER mode is set.
Setting positioning data
When using position-speed switching control, set the following positioning data.
: Always set, : Set as required, : Setting not required
*1 Refer to the following for information on the setting details.
Page 445 Positioning Data
Setting item Setting required/not required
[Da.1] Operation pattern
[Da.2] Control method
(Set "Forward run: position/speed" or "Reverse run: position/speed".)
[Da.3] Acceleration time No.
[Da.4] Deceleration time No.
[Da.6] Positioning address/movement amount
[Da.7] Arc address
[Da.8] Command speed
[Da.9] Dwell time/JUMP destination positioning data No.
[Da.10] M code/Condition data No./Number of LOOP to LEND repetitions/
Number of pitches
[Da.20] Axis to be interpolated No.1
[Da.21] Axis to be interpolated No.2
[Da.22] Axis to be interpolated No.3
[Da.27] M code ON signal output timing
[Da.28] ABS direction in degrees
[Da.29] Interpolation speed designation method