284
8 CONTROL SUB FUNCTIONS
8.9 Other Functions
Reading M codes
"M codes" are stored in the following buffer memory when the M code ON signal turns ON.
n: Axis No. - 1
Refer to the following for information on the storage details.
Page 468 Monitor Data
The following shows a program example for reading the "[Md.25] Valid M code" to the data register (D110) of the CPU
module. (The read value is used to command the sub work.)
Read M codes not as "rising edge commands", but as "ON execution commands".
Program example
Refer to the following for the program example.
Monitor item Monitor
value
Storage details Buffer memory address
[Md.25] Valid M code The M code No. ([Da.10] M code/Condition data No./Number
of LOOP to LEND repetitions/Number of pitches) set in the
positioning data is stored.
2408+100n
Classification Label name Description
Module label RD77_1.stnAxMntr[0].uStatus.C Axis 1 M code ON
RD77_1.stnAxMntr[0].uM_Code Axis 1 Valid M code
Global label, local label Defines the global label or the local label as follows. The settings of Assign (Device/Label) are not required for the label that the
assignment device is not set because the unused internal relay and data device are automatically assigned.