600o600
CEILING
CASSETTE
CEILING
CONCEALED
OUTDOOR
UNIT
B.1 600 o 600 CEILING CASETTE (SLZ) ....................................................B-3
Combination Table .........................................................................................B-2
SLZ-KA25VA
SLZ-KA25VAL
SLZ-KA35VA
SLZ-KA35VAL
SLZ-KA50VA
SLZ-KA50VAL
B.2 CEILING CONCEALED (SEZ) ................................................................B-39
SEZ-KD25VA
SEZ-KD25VAL
SEZ-KD35VA
SEZ-KD35VAL
SEZ-KD50VA
SEZ-KD50VAL
SEZ-KD60VA
SEZ-KD60VAL
SEZ-KD71VA
SEZ-KD71VAL
B.3 OUTDOOR UNIT (SUZ)..........................................................................B-85
SUZ-KA25VA
SUZ-KA35VA
SUZ-KA50VA
SUZ-KA60VA
SUZ-KA71VA
S series Model List

Other manuals for Mitsubishi Electric SUZ-KA60VA

Questions and Answers:

Mitsubishi Electric SUZ-KA60VA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelSUZ-KA60VA
CategoryAir Conditioner
LanguageEnglish

Summary

B.1 600x600 CEILING CASSETTE (SLZ)

B.1.1 SPECIFICATIONS

Detailed technical specifications for the SLZ series ceiling cassette units.

B.1.2 OUTLINES AND DIMENSIONS

Physical dimensions, installation diagrams, and component layouts for indoor units and controllers.

B.1.3 WIRING DIAGRAM

Electrical wiring diagrams for the SLZ series, showing connections for indoor and outdoor units.

B.1.4 REFRIGERANT SYSTEM DIAGRAM

Schematic illustrating the refrigerant flow and key components of the system.

B.1.5 PERFORMANCE DATA

Tables detailing cooling and heating performance data under various conditions.

B.1.6 4-WAY AIR FLOW SYSTEM

Information on fresh air intake, static pressure characteristics, and duct connection.

B.1.7 NOISE CRITERIA CURVES

Graphs showing sound pressure levels across different frequencies for various models.

B.1.8 OUTLET AIR SPEED AND COVERAGE RANGE

Data on airflow speed and the distance air can reach at different settings.

B.1.9 CENTER OF GRAVITY POSITION

Coordinates (X, Y, Z) indicating the center of gravity for mounting purposes.

B.1.10 REMOTE CONTROLLER

Explanation of buttons and functions for both wireless and wired remote controllers.

B.1.11 TROUBLESHOOTING

Guidance on diagnosing and resolving common issues and error codes.

B.1.12 INSTALLATION PROCEDURE

Step-by-step instructions for installing the indoor and outdoor units, including safety precautions.

B.2 CEILING CONCEALED (SEZ)

B.2.1 SPECIFICATIONS

Detailed technical specifications for the SEZ series ceiling concealed units.

B.2.2 OUTLINES AND DIMENSIONS

Physical dimensions, installation diagrams, and component layouts for SEZ indoor units.

B.2.3 WIRING DIAGRAM

Electrical wiring diagrams for the SEZ series, showing connections for indoor and outdoor units.

B.2.4 REFRIGERANT SYSTEM DIAGRAM

Schematic illustrating the refrigerant flow and key components for SEZ units.

B.2.5 PERFORMANCE DATA

Tables detailing cooling and heating performance data for various SEZ models.

B.2.6 NOISE CRITERIA CURVES

Graphs showing sound pressure levels for SEZ units under different static pressures.

B.2.7 INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW

Fan performance curves illustrating airflow rate versus external static pressure for SEZ indoor units.

B.2.8 CENTER OF GRAVITY POSITION

Coordinates (W, L, X, Y, Z) indicating the center of gravity for SEZ indoor units.

B.2.9 REMOTE CONTROLLER

Explanation of buttons and functions for wired and wireless remote controllers used with SEZ units.

B.2.10 TROUBLESHOOTING

Guidance on diagnosing and resolving common issues and error codes for SEZ units.

B.2.11 INSTALLATION PROCEDURE

Step-by-step instructions for installing SEZ indoor units and related components.

B.3 OUTDOOR UNIT (SUZ)

B.3.1 OUTLINES AND DIMENSIONS

Physical dimensions and required space for SUZ outdoor units (KA25-KA71VA).

B.3.2 WIRING DIAGRAM

Electrical wiring diagrams for SUZ outdoor units, showing connections to indoor units and power.

B.3.3 REFRIGERANT SYSTEM DIAGRAM

Schematic illustrating the refrigerant flow and components for SUZ outdoor units.

B.3.4 PERFORMANCE CURVES

Graphs showing capacity and input correction factors based on outdoor conditions.

B.3.5 NOISE CRITERIA CURVES

Sound pressure level curves for SUZ outdoor units under various operating conditions.

B.3.6 ACTUATOR CONTROL

Explanation of how sensors and actuators control compressor, fan, and valves.

B.3.7 TROUBLESHOOTING

Guidance on diagnosing and resolving common issues for SUZ outdoor units.

B.3.8 EARTHQUAKE-PROOF STRENGTH ANALYSIS

Calculation of anchor bolt strength requirements based on seismic coefficients and unit weight.

B.3.9 CAPACITY CORRECTION RATIO CURVE PIPING LENGTH

Curves showing how piping length affects cooling and heating capacity.

B.3.10 INSTALLATION PROCEDURE

Step-by-step instructions for installing the SUZ outdoor unit, including safety and site selection.