4.4 Wiring
4.4.1 Wiring
This section explains how to connect cables to the MES interface module.
For the equipment required for 10BASE-T/100BASE-TX connection and system
configuration examples, refer to the following.
Section 2.1.4 System configuration for operation
Section 2.3 Connection System Equipment
4.4.2 Wiring precautions
To establish a reliable system and fully utilize the MES interface module functions, make
wiring so that noise effect can be reduced.
(1) Sufficient safety measures must be taken when constructing the 100BASE-TX
and 10BASE-T networks.
Consult a specialist when connecting connection cable terminals, installing
main line cables, etc.
(2) Use a 10BASE-T/100BASE-TX connection cable compliant with the following
standards.
Section 2.3 Connection System Equipment
(3) The bending radius near the connector should be at least four times longer
than the cable's outside diameter.
(4) Connect the device on other end according to its specifications.
Figure 4.6 Wiring
MES interface module
HUB
Intranet
Twisted pair cable
(Straight)
RD
SD/
100
M
100BASE-TX
10BASE-T/
QJ71MES96N
CF CARD
PULL
RUN
ERR.
QJ71MES96N