1-57
Error no. L6670
1Error list
L6670 Error message Illegal OUT reset pattern
Cause The parameters are not defined in sets of 8 characters.
Measures Correct the parameters.
L6800 * Error message "Cancel pseudo-input mode, PW OFF"
Cause If pseudo input was canceled, it is necessary to turn the power ON again in order to prevent the erroneous
operation of the robot by external input signals.
Measures Turn the power OFF and then ON once. It switches to an external input signal.
C6900 Error message Pseudo-input signal mode
Cause Set with the parameters.
Measures To set a real signal, reset the parameter and then turn the power ON again.
C7000 Error message Copy source file was not found
Cause The copy source file was not found.
Measures Input the correct file name.
C7010 Error message Delete target file was not found
Cause The delete target file was not found.
Measures Input the correct file name.
C7020 Error message Rename target file was not found
Cause The rename target file was not found.
Measures Input the correct file name.
H7030 * Error message System error (param size over)
Cause The change capacity is too large.
Measures Contact the maker.
C7040 Error message Parameter changes prohibited
Cause Changing this parameter is prohibited as it is a dangerous parameter.
Measures Contact the maker.
H7050 Error message File is illegal
Cause This file is damaged.
Measures Contact to the dealer.
H7060 * Error message System error (RAM area full)
Cause The capacity has been exceeded.
Measures Contact the maker.
C7070 Error message Memory area is full
Cause The program and data have already exceeded the capacity.
Measures Delete any unnecessary programs or data.
L7071 Error message Not enough memory area for CTN
Cause Continue function needs more than 100Kbytes memory area.
Measures Delete any unnecessary programs.
C7080 Error message Can not read parameter
Cause Non-existent parameter or illegal password.
Measures 1. Input the correct parameter name.
2. Input the correct password
Error No. Error cause and measures

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi CR800 Series and is the answer not in the manual?

Mitsubishi CR800 Series Specifications

General IconGeneral
BrandMitsubishi
ModelCR800 Series
CategoryController
LanguageEnglish

Related product manuals