1-65
Error no. H8580
1Error list
H8580 Error message PROFIBUS I/O composition error.
Cause Any one of the following causes may be responsible:
(1) Data module is not of word type.
(2) Swap set value is outside the prescribed range.
(3) Data alignment mode set value is outside the prescribed range.
(4) Number-of-data modules set value is outside the prescribed range.
(5) Data module settings are outside the prescribed range.
(6) Parameter setting station numbers are invalid.
Measures Check the slave parameter settings on the Master Station. (Refer to the instruction manual for Master
Station.)
L8600 Error message The vision is a unconnection
Cause The vision is a unconnection
Measures Please check Com No. and Parameter
L8601 Error message The vision can't be logged on
Cause The parameter of the user-name or the password is abnormal
Measures Please set the parameter correctly
L8602 Error message Password is abnormal
Cause The password of the user-name is not corresponding
Measures Please set the password correctly
L8603 Error message Parameter is abnormal
Cause The parameter of the user-name or the password is abnormal
Measures Please set the parameter correctly
L8610 Error message The communication is abnormal
Cause The communication was cut
Measures Please check the communications cable
L8620 Error message The vision number is abnormal
Cause The number is not designated by NVOpen
Measures Please check NVOpen command
L8621 Error message Vision program name is abnormal
Cause The vision program name has exceeded 15 characters
Measures Please make the program name within 15 characters
L8622 Error message There is no vision program
Cause There is no specified vision program
Measures Please check the vision program name
Check whether "Job Server" has been enabled. If "Job Server" is enabled, disable it.
L8623 Error message SKIP number is already used
Cause SKIP number is already used
Measures Please confirm the SKIP number
L8630 Error message The recognition cell is illegal
Cause There is no value on the cell
Measures Please check the recognition cell
L8631 Error message The cell is outside the range
Cause The range of the cell is exceeded
Measures Please check the range of the cell
L8632 Error message The vision is a time-out
Cause There is no response from the vision
Measures Please check the time-out time
L8633 Error message The vision is a time-out (NVTRG)
Cause There is no response from the vision (NVTRG)
Measures Please decrease the load of the network
Error No. Error cause and measures