Electro-magnetic interference (EMI) and leakage currents
80
PRECAUTIONS FOR USE OF THE INVERTER
3.1.3 Built-in EMC filter
This inverter is equipped with a built-in EMC filter (capacitive filter) and a common mode choke.
These filters are effective in reducing air-propagated noise on the input side of the inverter.
To enable the EMC filter, fit the EMC filter ON/OFF connector to the ON position. The EMC filter is initially set to the "disabled"
(OFF) position for the FM type (with a built-in C3 filter). The EMC filter is initially set to the "enabled" (ON) position for the FM
type (with a built-in C2 filter) and the CA type.
The input side common mode choke, which is built in the inverter, is always enabled regardless of the EMC filter ON/OFF
connector setting.
FILTER
OFF ON
FILTER
OFF ON
FILTER
FILTER
OFF
ON
FILTER
FILTER
OFF
ON
FILTER
OFFON
FILTER
OFFON
EMC filter OFF EMC filter ONEMC filter OFF EMC filter ON EMC filter ONEMC filter OFF
FR-A846-00250(7.5K) to
00470(18.5K)
FR-A846-00250(7.5K) to 01160(45K)
FR-A846-00023(0.4K) to
00170(5.5K)
FR-A846-00023(0.4K) to 00170(5.5K)
FR-A846-00620(22K) to
01160(45K)
FR-A846-01800(55K) to 03610(132K)
FR-A846-01800(55K) to
03610(132K)