33
OPERATION
4.3.1 Mode switchover (Pr.0)
(1) FR-BU2 mode (setting value "0" (initial value))
Set this value when replacing the FR-BU type brake unit or using with the
GRZG type brake resistor, FR-BR-(H) type resistor unit or MT-BR5 type
resistor unit for the first time.
(2) BU mode (setting "1")
Set this value when replacing the existing BU type brake unit.
Connecting the GRZG type brake resistor provides the same braking
capability with the BU type brake unit.
Available with the FR-BU2-1.5K to 15K and FR-BU2-H7.5K to H30K only.
(3) MT-BU5 mode (setting "2")
Set this value when replacing the existing MT-BU5 type brake unit.
Connecing the MT-BU5 type resistor unit provides the same braking
capability as the MT-BU5.
Available with the FR-BU2-55K and FR-BU2-H75K only.
Change the setting when replacing the BU type brake unit and MT-
BU5 brake unit. When replacing the FR-BU type brake unit or using
with the GRZG type brake resistor, FR-BR-(H) resistor unit or MT-BR5
type resistor unit for the first time, use this parameter with initial value
"0" set.
Parameter
Number
Name
Initial
Value
Setting
Range
Description
0 Brake mode switchover 0
0 FR-BU2 mode
1
*1 BU mode
2
*2 MT-BU5 mode
*1 Available with the FR-BU2-1.5K to 15K and FR-BU2-H7.5K to H30K only.
*2 Available with the FR-BU2-55K and FR-BU2-H75K only.
*3 Perform the above parameter setting only when the inverter is at a stop.
REMARKS
Refer to page 13 for combination of the brake resistor and resistor unit.