38
OPERATION
4.3.5 Parameter clear
POINT
Set "1" in CLr All parameter clear
to initialize all parameters.
Parameters are not cleared when "1" is set in Pr. 77 Parameter write
selection
.
Operation Display
1. Screen at powering on
The mode is changed to monitor
mode.
2. Press to choose the
parameter setting mode.
3. Press ( ) until
(Parameter clear)
appears.
4. Press to read the currently
set value. " "(initial value)
appears.
5. Press ( ) to change
it to the set value " ".
6. Press to set.
Flicker...parameter clear complete!!
Press ( ) to read another parameter.
Press to show the setting again.
CAUTION
Pr.78 Cumulative energization time carrying-over times is not cleared.
The parameter
number read
previously
appears.