INSTALLATION
2 INSTALLATION
•Install the brake unit under the following conditions.
When encasing multiple
brake units, install them
in parallel as a cooling
measure.
Encasing multiple brake units
Remove the
front cover and
wiring cover to
fix the brake unit
to the surface.
Enclosure surface mounting
Leave enough clearances as
a cooling measure.
Vertical mounting
Vertical
Clearances
10cm or more
10cm or more
Temperature: -10 to 50
Humidity: 90%RH maximum
Ambient temperature
and humidity
5cm5cm
5cm
Brake unit
Measurement
position
Measurement
position
Brake units
can be closely
attached when
mounting in
lateral direction.*
* Permissible ambient
temperature is -10 to 40
when mounting brake units
closely-attached. When
ambient temperature exceeds
40 , clearances
between brake units should be
1cm or more.