PARAMETERS
98
Note:1. The frequenc
can be varied b
RH
acceleration
and RM
deceleration
between 0 and the maximum frequency (Pr. 1 or Pr. 18 setting).
2. When the acceleration or deceleration si
nal switches on, the set frequenc
varies accordin
to the slope set in Pr. 44 or Pr. 45. The output frequenc
acceleration/deceleration times are as set in Pr. 7 and Pr. 8, respectivel
.
Therefore, the lon
er preset times are used to var
the actual output
frequency.
3. If the start si
nal
STF or STR
is off, turnin
on the acceleration
RH
or
deceleration (RM) signal varies the set frequency.
REMARKS
A restart (STF signal ON) after ON-OFF of the clear signal (RL) should be made
after more than 1 minute has elapsed. The output frequency provided when a restart
is made within 1 minute is the output frequency given after the clear signal (RL) is
turned off (multi-speed frequency).
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Clear (RL)
Acceleration (RH)
Forward rotation (STF)
Power supply
(*2)
(*1)
Output
frequency(Hz)
More than 1 minute
1 minute or less
(*1) External operation frequency or PU operation frequency except multi-speed
(*2) Multi-speed frequency
CAUTION
When selecting this function, re-set the maximum frequency according to the
machine.
4