57
(3) Parameter clear
Initializes the parameter values to the factory settings. The calibration values are not
initialized.
(Parameter values are not cleared by setting "1" in Pr. 77 "parameter write disable
selection")
Cancel
SET
SET
Flicker
SET
Note:1. In the FR-E520-0.1K to 7.5K-NA and FR-E510W-0.1K to 0.75K-NA, Pr. 122
"communication check time interval" setting is "0". (Factory setting: 9999)
2. The Pr. 75, Pr. 180 to Pr. 183, Pr. 190 to Pr. 192, and Pr. 900 to Pr. 905
values are not initialized.
(4) All clear
Initializes the parameter values and calibration values to the factory settings.
Cancel
SET
SET
Flicker
SET
Note:1. In the FR-E520-0.1K to 7.5K-NA and FR-E510W-0.1K to 0.75K-NA, Pr. 122
"communication check time interval" setting is "0". (Factory setting: 9999)
2. The Pr. 75 value is not initialized.
3