PARAMETERS
61
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory
Setting
EC
Version
Refer
To
Page:
Cust-
omer
Set-
ting
41 Up-to-frequency sensitivity 0 to 100% 0.1% 10% 83
42 Output frequency detection 0 to 120Hz 0.01Hz 6Hz 84
Output
terminal
functions
43
Output frequency detection for reverse
rotation
0 to 120Hz, 9999 0.01Hz 9999 84
44 Second acceleration/deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s 5 s 70
45 Second deceleration time
0 to 3600 s/0 to 360 s,
9999
0.1 s/0.01 s 9999 70
46 Second torque boost 0 to 30%, 9999 0.1% 9999 66
47 Second V/F (base frequency) 0 to 120Hz, 9999 0.01Hz 9999 68
48 Second stall prevention operation current 0 to 150% 0.1% 120% 85
49
Second stall prevention operation
frequency
0 to 120Hz, 9999 0.01 0 85
Second functions
50 Second output frequency detection 0 to 120Hz 0.01Hz 30Hz 84
$
52 DU/PU main display data selection
0, 5, 6, 8, 10 to 14, 17,
20, 23, 24, 25, 100
1086
$
53 PU level display data selection
0 to 3, 5, 6, 8, 10 to 14,
17
1186
$
54 FM terminal function selection
1 to 3, 5, 6, 8, 10 to 14,
17, 21
1186
$
55 Frequency monitoring reference 0 to 120Hz 0.01Hz
60Hz
50Hz
88
Display functions
$
56 Current monitoring reference 0 to 500A 0.01A
Rated
output
current
88
$
57 Restart coasting time 0, 0.1 to 5 s, 9999 0.1 s 9999 89
Automatic
restart
functions
$
58 Restart cushion time 0 to 60 s 0.1 s 1.0 s 89
Additional
function
59 Remote setting function selection 0, 1, 2 1 0 91
$
60 Intelligent mode selection 0, 3, 4, 9 1 0 93
61 Reference I for intelligent mode 0 to 500A, 9999 0.01A 9999 94
62 Ref. I for intelligent mode accel. 0 to 150%, 9999 0.1% 9999 94
63 Ref. I for intelligent mode decel. 0 to 150%, 9999 0.1% 9999 94
$
65 Retry selection 0 to 5 1 0 95
$
66
Stall prevention operation level reduction
starting frequency
0 to 120Hz 0.01Hz
60Hz
50Hz
77
$
67 Number of retries at alarm occurrence 0 to 10,101 to 110 1 0 95
$
68 Retry waiting time 0 to 10 s 0.1 s 1 s 95
$
69 Retry count display erasure 0

095
$
71 Applied motor 0, 1, 2 1 0 97
$
72 PWM frequency selection 0 to 15 1 2 98
$
73 0-5V/0-10V selection 0 to 5, 10 to 15 1 1 99
$
74 Filter time constant 0 to 8 1 1 100
$
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17 1 14 100
$
76 Alarm code output selection 0, 1, 2 1 0 102
$
77 Parameter write disable selection 0, 1, 2 1 0 103
$
78 Reverse rotation prevention selection 0, 1, 1 0 104
Operation selection functions
$
79 Operation mode selection 0 to 4, 6 to 8 1 0 105
100 V/F1 (first frequency) 0 to 120Hz, 9999 0.01Hz 9999 108
101 V/F1 (first frequency voltage) 0 to 1000V 0.1V 0 108
102 V/F2 (second frequency) 0 to 120Hz, 9999 0.01Hz 9999 108
103 V/F2 (second frequency voltage) 0 to 1000V 0.1V 0 108
104 V/F3 (third frequency) 0 to 120Hz, 9999 0.01Hz 9999 108
105 V/F3 (third frequency voltage) 0 to 1000V 0.1V 0 108
5-point flexible V/F
characteristics
106 V/F4 (fourth frequency) 0 to 120Hz, 9999 0.01Hz 9999 108