EasyManua.ls Logo

Mitsubishi FR - S500 - E2 PROM Write Selection (N12 )

Mitsubishi FR - S500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150
Communication parameters
2.15.4 E
2
PROM write selection (n12 )
The parameter number in parentheses is the one for use with the parameter unit (FR-
PU04).
You can choose whether the parameters are stored into the E
2
PROM or not at
the parameter setting for computer communication. When performing parameter
write frequently, write them to the RAM.
Parameter Name
Factory
Setting
Setting
Range
Remarks
n12 (342)
E
2
PROM write
selection
00, 1
0: Written to RAM and E
2
PROM
1: Written to RAM only
Not written to E
2
PROM*
Setting is enabled when Pr. 30 = "1"
REMARKS
*When the parameter setting is "not written to E
2
PROM" (setting=1), the settings return to the
original values (values saved in the E
2
PROM) at power-on reset or terminal reset.