7
Main circuit terminals
1
WIRING
3) Single-phase 100V power input
FR-S510WE-0.1K, 0.2K, 0.4K-NA FR-S510WE-0.75K-NA
CAUTION
Make sure the power cables are connected to the R/L1, S/L2, T/L3 of the inverter.
Never connect the power cable to the U, V, W of the inverter. (Phase need not be
matched)
Connect the motor to U, V, W. At this time, turning on the forward rotation switch
(signal) rotates the motor in the counterclockwise direction when viewed from the
motor shaft.
Motor
U V W
IM
Power supply
R/L1 S/L2
P/+N/-
Motor
U V W
IM
Power supply
P/+
N/-
R/L1 S/L2