EasyManua.ls Logo

Mitsubishi FR - S500 - Page 192

Mitsubishi FR - S500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
182
Parameter Instruction Code List
Display functions
52
Operation panel display
data selection
34 B4 1 0
53
Frequency setting
operation selection
35 B5 1 0
54
AM terminal function
selection
36 B6 1 0
55
Frequency monitoring
reference
37 B7 0.01Hz 0
56
Current monitoring
reference
38 B8 0.01A 0
Automatic
restart
functions
57 Restart coasting time 39 B9 0.1s 0
58 Restart cushion time 3A BA 0.1s 0
Additional
function
59
Remote setting function
selection
3B BB 1 0
Te rm i n al
functions
selection
60
RL terminal function
selection
3C BC 1 0
61
RM terminal function
selection
3D BD 1 0
62
RH terminal function
selection
3E BE 1 0
63
STR terminal function
selection
3F BF 1 0
64
RUN terminal function
selection
40 C0 1 0
65
A, B, C terminal function
selection
41 C1 1 0
Operation selection functions
66 Retry selection 42 C2 1 0
67
Number of retries at
alarm occurrence
43 C3 1 0
68 Retry waiting time 44 C4 0.1s 0
69 Retry count display erase 45 C5 1 0
70 Soft-PWM setting 46 C6 1 0
71 Applied motor 47 C7 1 0
72 PWM frequency selection 48 C8 1 0
73 0-5V/0-10V selection 49 C9 1 0
74 Input filter time constant 4A CA 1 0
75
Reset selection/PU stop
selection
4B CB 1 0
76
Cooling fan operation
selection
4C CC 1 0
77
Parameter write disable
selection
4D None 1 0
78
Reverse rotation
prevention selection
4E CE 1 0
Func-
tion
Parameter
Number
Name
Instruction
Code
Computer
Link Data
Setting
Increments *
Link Parameter
Extension Setting
(Instruction
Code 7F/FF)
Read Write

Table of Contents