60
Function (Parameter) list
Parameter List
PU parameters
When the parameter unit (FR-PU04) is used, operation from the operation panel is
not accepted. (The stop key ( ) is valid)
Func
tion
Parame-
ter
Indica-
tion
Name Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
PU parameters
n13
(145)
PU display
language
selection
0: Japanese,
1: English,
2: German,
3: French,
4: Spanish,
5: Italian,
6: Swedish,
7: Finish
11151
n14
(990)
PU buzzer
control
0: Without sound,
1: With sound
11151
n15
(991)
PU contrast
adjustment
158152
n16
(992)
PU main display
screen data
selection
0: Selectable
between
output
frequency and
output current
100:
(during stop):
Set frequency,
output current
(during
operation):
Output
frequency, output
current
10152
n17
(993)
disconnected PU
detection/PU
setting lock
0: Without
disconnected
PU error,
1: Error at
disconnected
PU,
10:Without
disconnected
PU error (PU
operation
disable)
10153
REMARKS
1.The parameter number in parentheses is the one for use with the parameter unit (FR-PU04).
2. Set "9999" when setting a value "- - -" using the parameter unit (FR-PU04).
3. The decimal places of a value 100 or more (3 digits or more) cannot be displayed.