Alarm indications
Alarm indications
There are many monitoring functions integrated in Hydrolution.
To alert you to any malfunctions, the control computer
transmits alarm signals that can be read from the front panel
display.
What happens in the event of an alarm?
The background lighting in the display starts ashing and
the status lamp lights red.
Some alarms change operating mode to Add. heat only.”
and reduce the supply temperature to the minimum
permitted temperature to notify you that something is
wrong.
Resetting alarms
No harm in resetting an alarm. If the cause of the alarm remains,
the alarm recurs.
When an alarm has been triggered, it can be reset by switching
indoor unit off and on using the switch (SF1).
When the alarm cannot be reset using the switch (SF1), the
operating mode, Add. heat only, can be activated to
resume a normal temperature level in the house. This is
most easily carried out by holding the Operating mode”
button in for 7 seconds.
Different types of alarms
Alarms w ith auto matic re set (do n ot n eed to b e
acknowledged when the cause has disappeared).
Existing alarms that require corrective action by you or the
installer.
Recommended actions
1. Read off which alarm has occurred from the heat pump
s
display.
2. As a customer you can rectify certain alarms. See the table
below for relevant actions. If the alarm is not rectied, or is
not included in the table, contact your installer.
Check/remedy before installers/service
technicians are called
Alarm descriptionAlarm text on the display
Check that the thermostats for the radiators/
under-floor systems are not closed.
Tripped low pressure sensor.LP-ALARM
Check that the thermostats for the radiators/
under-floor systems are not closed.
Tripped high pressure sensor.HP-ALARM
Check that any circuit breakers to the outdoor
unit are not off.
Outdoor unit not powered / Communication
cut
OU power failure / OU Com. error
Check and replace any blown circuit and
main fuses.
Display not lit
Check that the circuit breaker to the indoor
unit is not off.
Check that the switch (SF1) is in normal posi-
tion (1).
NOTE
Recurring alarms mean that there is a fault in the
installation.
Contact your installer!

Other manuals for Mitsubishi HMA100V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi HMA100V and is the answer not in the manual?

Mitsubishi HMA100V Specifications

General IconGeneral
BrandMitsubishi
ModelHMA100V
CategoryHeat Pump
LanguageEnglish

Related product manuals