15. Removing the compressor (MC)
(1)Removetheservicepanel.(SeeFigure1)
(2)Removethetoppanel.(SeeFigure1)
(3)Remove2frontcoverpanelfixingscrews(5×12)and
removethefrontcoverpanel.(SeeFigure1)
(4)Remove2backcoverpanelfixingscrews(5×12)and
removethebackcoverpanel.
(5)Removetheelectricalpartsbox.(SeePhoto3)
(6)Remove3valvebedfixingscrews(4×10),4ballvalveand
stopvalvefixingscrews(5×16),thenremovethevalvebed.
(7)Remove3rightsidepanelfixingscrews(5×12)inthe
rearoftheunitandthenremovetherightsidepanel.
(8)Remove3separatorfixingscrews(4×10)andremovethe
separator.
(9)Removethethermistor<Comp.surface>(TH32).(Referto
procedure7)
(10)Recoverrefrigerant.
(11)Removethe3pointsofthemotorforcompressorfixing
nutusingspanneroradjustablewrench.
(12)Removetheweldedpipeofmotorforcompressorinlet
andoutletandthenremovethecompressor.
Note: Recover refrigerant without spreading it in the air.
16. Removing the accumulator
(1)Removetheservicepanel.(SeeFigure1)
(2)Removethetoppanel.(SeeFigure1)
(3)Remove2frontcoverpanelfixingscrews(5×12)and
removethefrontcoverpanel.(SeePhoto3)
(4)Remove2backcoverpanelfixingscrews(5×12)and
removethebackcoverpanel.
(5)Removetheelectricalpartsbox.(SeeFigure1)
(6)Remove3valvebedfixingscrews(4×10),4ballvalveand
stopvalvefixingscrews(5×16),thenremovethevalvebed.
(7)Remove3rightsidepanelfixingscrews(5×12)intherear
oftheunitandthenremovetherightsidepanel.
(8)Recoverrefrigerant.
(9)Remove2weldedpipesofaccumulatorinletandoutlet.
(10)Remove2receiverlegfixingscrews(4×10).
Note: Recover refrigerant without spreading it in the air.
Photo 14
Accumulatorleg
fixingscrews
Compressor
(MC)
Accumulator
Compressor
fixingnuts
Accumulator
Accumulator
leg
Inlet
Outlet
Photo 15
14. Removing the reactor (DCL) (A30, 36)
(1)Removetheservicepanel.(SeeFigure1)
(2)Removethetoppanel.(SeeFigure1)
(3)Removetheelectricalpartsbox.(SeePhoto3)
(4)Remove4reactorfixingscrews(4×10)andremovethe
reactor.
Note:Thereactorisattachedtotherearoftheelectricalpartsbox
.
Reactorfixingscrews
Reactorfixingscrews
Reactor
(DCL)
Photo 13
Electricalpartsbox
OPERATING PROCEDURE