EasyManua.ls Logo

Mitsubishi PUZ-A18NHA6 - Noise

Mitsubishi PUZ-A18NHA6
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
TABP
Connecttothe
smoothingcapacitor
CB+
(A42Nonly)
Outdoor power circuit board
PUZ-A30/36/42NHA6
PUZ-A30/36/42NHA6-BS
PUY-A30/36/42NHA6
PUY-A30/36/42NHA6-BS
TABP1
Connectto52C
TABP2/SC-P2
Connectto
ACTM
CN4
Connecttothe
outdoorcontroller
circuitboard(CN4)
CN2
Connecttotheoutdoorcontrollercircuitboard
(CN2)
15:Transmittingsignaltotheoutdoor
controllercircuitboard(0–5VDC)
25:Zerocrosssignal(0–5VDC)
34:18VDC
65:16VDC
75:16VDC
CN3
Thermistor(TH8)
<Heatsink>
CN5
Detectionofprimary
current
Connecttothe
outdoornoisefilter
circuitboard(CN5)
CNDC
280–380VDC(1+,3−)
Connecttotheoutdoor
controllercircuitboard
TABS/TABT
Connecttothe
outdoornoisefil-
tercircuitboard
Voltageamong
phases:208/230
VAC
Brief check of POWER MODULE
Usually,theyareinastateofbeingshort-circuitediftheyarebroken.
Measuretheresistanceinthefollowingpoints(connectors,etc.).
Iftheyareshort-circuited,itmeansthattheyarebroken.
1.Checkofdiodebridge
TABP1-TABS,TABN1-TABS,TABP1-TABT,TABN1-TABT
2.CheckofDIP-IPM
P-U,P-V,P-W,N-U,N-V,N-W
TABN2
ConnecttoACTM
TABN
Connecttothe
smoothingcapacitor
CB
(A42Nonly)
TABU/V/W
Connecttothecompressor(MC)
Voltageamongphases:10–180VAC
TABN1
Connectto
ACTM
DIP-IPM
CNAF
ConnecttoACTM
OCH577A

Related product manuals