35
<Abnormalities detected while unit is operating>
Check code
Abnormal point and detection method
Judgment and action
U1
(1302)
High pressure (High-pressure switch
63H operated)
Abnormalifhigh-pressureswitch63H
worked(*)duringcompressoroperation.
*602PSIG[4.15MPa]
63H:High-pressureswitch
1Shortcycleofindoorunit
2Cloggedfilterofindoorunit
3Decreasedairflowcausedby
dirtofindoorfan
4Dirtofindoorheatexchanger
5Lockedindoorfanmotor
6Malfunctionofindoorfanmotor
7Defectiveoperationofstop
valve(Notfullopen)
8Cloggedorbrokenpipe
9Lockedoutdoorfanmotor
0Malfunctionofoutdoorfan
motor
1Shortcycleofoutdoorunit
2Dirtofoutdoorheatexchanger
3Decreasedairflowcausedby
defectiveinspectionofoutside
temperaturethermistor
(Itdetectslowertemperature
thanactualtemperature.)
4Disconnectionorcontactfailure
ofconnector(63H)onoutdoor
controllerboard
5Disconnectionorcontactfailure
of63Hconnection
6Defectiveoutdoorcontroller
board
7Defectiveactionoflinear
expansionvalve
8Malfunctionoffandrivingcircuit
1–6Checkindoorunitandrepairthedefect.
7Checkifstopvalveisfullyopen.
8Checkpipingandrepairthedefect.
9–2Checkoutdoorunitandrepairthedefect.
3Checktheinspectedtemperatureofoutside
temperaturethermistoronLEDdisplay.
(SW2onA-ControlServiceTool:Refer
to"10-10.FUNCTIONOFSWITCHES,
CONNECTORSANDJUMPERS".)
4–6TurnthepoweroffandcheckF5is
displayedwhenthepowerisonagain.
WhenF5isdisplayed,referto“Judgment
andaction”forF5.
7Checklinearexpansionvalve.
Referto"10-6.HOWTOCHECKTHE
PARTS"and"10-7.HOWTOCHECKTHE
COMPONENTS".
8Replaceoutdoorcontrollerboard.
Case
U2
(TH32:1132)
High discharge temperature
High comp. surface temperature
(1)
Abnormalifdischargetemperaturether-
mistor(TH32)exceeds257˚F[125:]
or230˚F[110:]continuouslyfor5min-
utes.
Abnormalifcondenser/evaporator
temperaturethermistor(TH5)exceeds
104˚F[40:]duringdefrostinganddis-
chargetemperaturethermistor(TH32)
exceeds230˚F[110:].
(2)Abnormalifdischargesuperheat
(Cooling:
TH32
−TH5
Heating:TH32−TH6)increases.
AlltheconditionsinAorBaredetected
simultaneouslyfor10minutescontinu-
ouslyafter6minutespastfromcom-
pressorstart-up(includingthethermo-
statindicationorrecoveryfromdefrost-
ing).
<ConditionA>
•Heatingmode
•Whendischargesuperheatisless
than126˚F[70:].
•WhentheTH6tempismorethanthe
valueobtainedbyTH7−9˚F[5:].
•WhenthecondensingtempofTH5is
lessthan95˚F[35:].
<ConditionB>
•Duringcomp.operation(Coolingand
Heating)
•Whendischargesuperheatisless
than144˚F[80:]incooling.
•Whendischargesuperheatisless
than162˚F[90:]inheating.
•WhencondensingtempofTH6is
morethan−40˚F[−40:](Incooling
only).
1Overheatedcompressoropera-
tioncausedbyshortageof
refrigerant
2Defectiveoperationofstop
valve
3Defectivethermistor
4Defectiveoutdoorcontroller
board
5Defectiveactionoflinear
expansionvalve
1Checkintakesuperheat.
Checkleakageofrefrigerant.
Chargeadditionalrefrigerant.
2Checkifstopvalveisfullyopen.
34TurnthepoweroffandcheckifU3isdis-
playedwhenthepowerisonagain.
WhenU3isdisplayed,referto“Judgment
andaction”forU3.
5Checklinearexpansionvalve.
Referto"10-6.HOWTOCHECKTHE
PARTS"and"10-7.HOWTOCHECKTHE
COMPONENTS".