APP -5 APP -5
A
PPENDICES
MELSEC-Q
Compatible CPU
No. Name Content Description
Setting Side
(Setting
Timing)
Basic model QCPU
High Performance
model QCPU
Process CPU
Redundant CPU
Universal model QCPU
SM331
Normal SFC program
execution status
OFF : Not executed
ON : Being executed
Indicates whether the normal
SFC program is being executed
or not.
Used as an execution interlock
of the SFC control instruction.
S (status
change)
2
4
SM332
Program execution
management SFC
program execution
status
OFF : Not executed
ON : Being executed
Indicates whether the program
execution management SFC
program is being executed or
not.
Used as an execution interlock
of the SFC control instruction.
S (status
change)
3
4 4
SM735
SFC comment
readout instruction in
execution flag
OFF : SFC comment
readout
instruction is
inactivated.
ON : SFC comment
readout
instruction is
activating.
• Turns on the instructions,
(S(P).SFCSCOMR) to read the
SFC step comments and (S(P).
SFCTCOMR) to read the SFC
transition condition comments.
System
(status
change)
1: Available with the CPU module whose function version is B or later
2: Applicable to the one whose first five digits of serial No. are "04122" or later.
3: Applicable to the one whose first five digits of serial No. are "07012" or later.
4: Applicable to the one whose first five digits of serial No. are "07032" or later.

Table of Contents

Other manuals for Mitsubishi Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Q Series and is the answer not in the manual?

Mitsubishi Q Series Specifications

General IconGeneral
I/O PointsUp to 4096 points
CommunicationEthernet, RS-232, RS-485
I/O ModulesDigital, Analog, Specialized
Programming LanguageFunction Block Diagram, Structured Text
Power Supply24V DC, 100-240V AC
Operating Temperature0°C to 55°C
Shock Resistance147 m/s2 acceleration, 3 times in each of X, Y, and Z directions
Program CapacityUp to 252K steps