8-20
Chapter 8 PERIODIC INSPECTION AND MAINTENANCE PROCEDURES
Air Cleaner - Check for Clogging
1. Check the air cleaner indicator for the element
clogging.
2. If the element is clogged, the red signal mark will
be displayed.
3. Immediately clean or replace the air cleaner ele-
ment when the signal turns red.
Note: (a) For cleaning of the air cleaner element, refer
to "Air Cleaner Element - Clean, Check and
Replace" (8-21).
(b) If the specification of air cleaner differs from
the contents of this operation manual, follow
the manufacturer's operation manual.
Fig. 8-26 Air Cleaner - Check for Clogging
Reset
button
Signal
(red)