12.9 Pressure table for standard operation
(1) TDJ300D
(2) TDJ430D
41
10 15 20 25 30 35 40
High pressureLow pressure
MPa(kgf/cm
2
)
MPa(kgf/cm
2
)
Return air temperature by condenser °C
(Outside air temperature)
Compressor revolution 1800min
-1
2.7 (28)
2.5 (26)
2.4 (24)
2.2 (22)
2.0 (20)
1.8 (18)
1.6 (16)
1.4 (14)
1.2 (12)
1.0 (10)
0.8 (8)
0.6 (6)
0.5 (5)
0.4 (4)
0.3 (3)
0.2 (2)
0.1 (1)
0 (0)
Storage
temperature -18°C
Storage
temperature 0°C
Storage
temperature -18°C
Storage
temperature 0°C
High pressureLow pressure
MPa(kgf/cm
2
)
MPa(kgf/cm
2
)
10 15 20 25 30 35 40
Return air temperature by condenser °C
(Outside air temperature)
Compressor revolution 1800min
-1
2.7 (28)
2.5 (26)
2.4 (24)
2.2 (22)
2.0 (20)
1.8 (18)
1.6 (16)
1.4 (14)
1.2 (12)
1.0 (10)
0.8 (8)
0.6 (6)
0.5 (5)
0.4 (4)
0.3 (3)
0.2 (2)
0.1 (1)
0 (0)
Storage
temperature -18°C
Storage
temperature -18°C
Storage
temperature 0°C
Storage
temperature 0°C