- 15 -
PARAMETER
4. Example of parameter settings
Procedure to correctly set parameters is shown.
4.1 DP-1 parameter setting procedure
By entering the parameter mode, parameters can be set. To enter the parameter setting
mode when the electrical power is OFF, simultaneously press 'DATA' key and
'POWER' key. Then, the unit will enter the parameter mode.
In the parameter input mode, the following key operations can change setting details.
Parameter setting key Time setting
Setting change
Set
Date setting
STAT
DATA
STAT
DATA
STAT
DATA
Increase time
Minutes increase
Prints time
Sets time
PRINTER
CL
PRINTER
CL
CE
Year increase
Month increase
Day increase
Prints date
Sets Date
Additional settings
Parameter clear
Letter size
Date
Time
Examples of settings are shown on the following pages.