Zeus200 Installation manual
V 1.0.7 - 12/10/2020 Page 27 of 28
Display shows
“External pump error”
- The cooling circuit line is not
working properly
- Check the correct circulation of water
from the seacock to the seawater
discharge
- Check the exchanger
- Check the cables and the relative
connections between the external pump
and the generator
Display shows
“Water pump error”
- Fault or lack of connection with
water pump
- Excessive heatsink temperature
due to air bubbles in the system
- Check connection and operation of the
water pump
- Purge the air present in the coolant.
Read the heatsink temperature (par.
3.1)
Display shows
“Spark plug fault”
- Fault or lack of connection with
the spark plug
- Check connection and functionality of
the burner spark plug
Display shows
“Water
overtemperature”
- Coolant temperature too high
- Wait for the coolant temperature to
drop
Display shows
“Water outlet probe
error”
- Fault or lack of connection with
outlet water probe
- Check sensor connection and operation
Display shows
“Water inlet probe
error”
- Fault or lack of connection with
inlet water probe
- Check sensor connection and operation
Display shows
“Fume probe error”
- Fault or lack of connection with
exhaust gas probe
- Check sensor connection and operation
Display shows
“Low liquid level”
- Insufficient cooling liquid
- Top up the coolant using the special
tank.
ATTENTION: for the top-up use only
specific cooling liquid
Display shows
“Wait for cooling”
- Generator temperature too
high to be able to perform a new
ignition
- Wait for the system to cool down. The
Zeus200 generator restarts when the
combustion chambers temperatures drop
below 100°C.
- Exhaust battery, not able to
store energy anymore
- One or more elements
damaged; battery does not reach
charge voltage level