4 Fault or malfunctions
The following table shows the most common causes of errors, together with the possible cause and
possible solutions.
- Check the fuse on the charging unit
- Verify that all cables are correctly
connected
- Battery charged
- High outdoor temperature
- Battery exhausted
- The burner at full power does
not reach 360/370°C
- The cooling system is not
efficient
- Verify the production of electricity
during the first recharge phase
- Verify the production of electricity with
lower temperatures
- Replace the battery
- Check the supply line enad the burner
efficiency
- Check the cooling liquid temperature
and the heat exchanger
Display shows
“Service batt. low”
- Low voltage of service battery
Display shows
“Service batt.
overtempt.”
- Service battery temperature
too high
- Place the service battery in a more
ventilated place
Display shows
“Engine batt. low”
- Low voltage of engine battery
- Turn on the generator and force the
charge on the engine battery
- Switch on vehicle’s engine, if possible
Display shows
“Too low battery”
- Primary battery voltage too
low. The generator may not be
able to turn on
- Charge the primary battery
- Switch on the vehicle’s engine in order
to raise the primary battery voltage and
start the generator using the manual
mode
Display shows
“Charged battery”
- Correct voltage on the primary
battery
- It is not needed to turn on the
generator
Display shows
“No communication”
- No communication between
display, central unit and / or
generator control unit
- Check cables and connections between
the display, the charging unit and / or
the generator
Display shows
“Combustion error”
- Low tank level
- Obstructed supply line
- Frozen fuel
- Refuel. Reset error and repeat ignition
- Remove the obstruction
- Wait for fuel defrosting
Display shows
“Burner fan error”
- Fault, obstruction or lack of
connection to the burner fan
- Check connection and rotation of the
burner fan
Display shows
“Fuel Pump error”
- Fault or lack of connection to
the fuel pump
- Check continuity of the power supply
cable and fuel pump operation