18
Hexadecimal 1B 44 n1 n2 n3… 00
Decimal 27 68 n1 n2 n3… 0
[Description]: Sets horizontal tab positions.
[Notice]:
n specifies the column number for setting a horizontal tab position from
the
beginning of the line.
k indicates the total number of horizontal tab positions to be set.
The horizontal tab position is stored as a value of [character width × n]
measured from the beginning of the line. The character width includes the
right-side character spacing, and double-width characters are set with
twice the width of normal characters.
This command cancels the previous horizontal tab settings.
When setting n = 8, the print position is moved to column 9 by sending
HT.
Up to 32 tab positions ( k = 32) can be set. Data exceeding 32 tab
positions is processed as normal data.
Transmit [ n] k in ascending order and place a NUL code 0 at the end.
When [ n] k is less than or equal to the preceding value [ n] k-1, tab
setting is finished and the following data is processed as normal data.
ESC D NUL cancels all horizontal tab positions.
The previously specified horizontal tab positions do not change, even if
the
character width changes.
The character width is memorized for each standard and page mode.
[Default] The default tab positions are at intervals of 8 characters (columns
9, 17, 25,...) for font A (12 ´ 24).
[Reference] HT
4.3.3 ESC \ nL nH
[Name]: Set relative printing position
[Format]: ASCII ESC \ nL nH
Hexadecimal 1B 5C nL nH
Decimal 27 92 nL nH
[Range]: 0 nL 255; 0 nH 1.
[Description]: Sets the print starting position based on the current position
by using the horizontal or vertical motion unit.
This command sets the distance from the current position to n [( nL + nH
×
256)horizontal motion unit]
[Notice]: