Fuse: A blown fuse can be an indication for an error within the complete
system. Have the fault eliminated by an authorised qualified
expert.
Technical data
Technical Data
S2 K2 K2E C2
Operating voltage: 230 V AC, -10%.. +10%
230 V
Switch current: max. 0,2 A*
Fuse: 0.63 A T
Safety class: II
Max. numbers of actuators: 5 á 3 W
Operating voltage: 24 V AC, -10%.. +20%
24 V
Switch current: max. 1 A*
Fuse: 1 A T
Safety class: III
Max. numbers of actuators: 5 á 3 W
Control oscillation: approx. 0.2 K
Degree of protection: IP30
Antifreeze operation: 5°C
Valve protection function: 6 min / 24h
Overcharge protection
external sensor
Assembly: Thermostat plug-in connection
Dimensions H/B/T in mm 80/84/27 80/93/27 80/93/27 80/118/27
Storage temperature: -25 to 60 °C
Ambiente temperature: 0 to 50 °C
Relative humidity: max. 80%, non-condensing
*resistive load
230 V 24 V
117012.1343