Eco Connect+ Convection | 4/5/7/10-Tray | Steam Installation and Operation Manual
100
MONO FG1BX-UK-MAN-0300 | Rev. C23 (July 2023)
Installation (condenser unit)
1. Ensure that all power is disconnected and the oven is cool.
2. Before fitting the main condenser assembly, insert a blanking plug (Figure 42 | A) into the lower hole that
is not required for this oven type.
3. Connect the tube (Figure 42 | B) to the spigot and retain it with a worm-drive clip (Figure 42 | C).
4. Place the condenser in position, ensuring that the tube (B) passes through the hole in the top of the oven
and worm drive clip (Figure 42 | D), then over the spigot of the damper assembly on the oven.
5. Tighten the worm-drive clip (D).
6. Fasten the condenser unit to the top of the oven with M6 x 12 mm long hex head screws and washers in
four positions. (If holes have been drilled, nuts must also be used).
7. Connect wiring, depending on whether the oven is a 4-tray or 10-tray version, as shown in the
corresponding Electricals manual.
8. Connect the drain hose to a suitable drain.
9. Attach a water tap bracket to the base frame, as shown, and fasten the water hose to a water supply.
(A tee pipe must be used on double ovens).
NOTE
If fixing holes are not present on the top sheet of the oven, they should be marked and drilled at this stage.
Position the condenser correctly and mark hole positions (centre of each slot). Remove the condenser and drill
holes of 6.5 mm diameter at four positions.