EasyManua.ls Logo

Motorola GP88s

Motorola GP88s
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Equipment 3-3
3.0 Test Equipment
Table 3-3 lists test equipment required to service the GP88s Radios and other two-way radios.
Table 3-3 Recommended Test Equipment
Motorola Part
No.
Description Characteristics Application
R2000, R2400,
or R2001 with
trunking option
Service Monitor This monitor will
substitute for items with
an asterisk *
Frequency/deviation meter
and signal generator for
wide-range troubleshooting
and alignment
*R1049 Digital Multimeter Two meters recommended
for AC/DC voltage and cur-
rent measurements
*S1100 Audio Oscillator 67 to 200Hz tones Used with service monitor for
injection of PL tones
*S1053,
*SKN6009,
*SKN6001
AC Voltmeter,
Power Cable for
meter, Test leads
for meter
1 mV to 300 V,
10 Megohm input
impedance
Audio voltage measure-
ments
R1053 Dual-trace Oscillo-
scope
20 MHz bandwidth,
5 mV/cm - 20 V/cm
Waveform measurements
*S1350, *ST1215
(VHF)
*ST1223 (UHF)
*T1013
Wattmeter,
Plug-in Elements
(VHF & UHF), RF
Dummy Load
50-Ohm, ±5% accuracy
10 W, max. 0-1000
MHz, 300 W
Transmitter power output
measurements
S1339 RF Millivolt Meter 100
µ
V to 3 VRF, 10
kHz to 1.2 GHz
RF level measurements
*R1013 SINAD Meter Receiver sensitivity mea-
surements
S1347 or
S1348 (prog)
DC Power Supply 0-20 Vdc, 0-5 Amps Bench supply for 7.5Vdc

Table of Contents

Related product manuals