DISPLAYS, MESSAGES, AND ALERTS: Power-Down Sequence
12 68P80401P05
3.2 Power-Down Sequence
To power down the unit, press and hold the Power key until the unit begins powering down.
3.3 Messages
3.3.1 Self-Test Errors
The following table contains the list of self-test non-reset errors. These errors are displayed as SELF
CHECK ERROR YXXXX (YXXXX represents the identifier for that error).
3.3.2 Self-Test Reset Errors
The following table contains the list of self-test reset errors. These errors are displayed as SELF
CHECK FAIL YXXXX (YXXXX represents the identifier for that error).
Table 3-1. Self-Test Errors
Y XXXX Description of Error
0 0001 Non-reset error log
0 0002 Codeplug error log
Table 3-2. Self-Test Reset Errors
Y XXXX Description of Error
0 0100 RAM failure
0 0200 Data lines failure
0 0400 Address line failure
0 0800 Codeplug corruption/invalid
0 1000 Flash checksum error
0 2000 Reset error logging
0 4000 Codeplug mismatch
F 4000 Ergo pre-self-test codeplug error
F 8000 Ergo pre-self-test invalid device or device failure
F 8002 Ergo pre-self-test invalid device or device failure
: 0800 FDI-related error