FIELD LEVEL TEST MODES AND PROCEDURES: Reset Log Test
8-12 68P80400P73-A
8.12 Reset Log Test
Use this test to check the reset log in the unit.
To perform the reset log test:
1. Power on the unit and wait until registration is complete.
2. If the unit does not have the latest software version, reflash (reprogram) the unit.
If the unit attempts to reset, perform the Reset test (see page 8-11).
3. Enter debug mode (see page 6-1). The Unit Info display appears.
4. Scroll down and highlight Resets, and then press View to view the Resets display.
5. Look for and record any reset errors. Refer to the iSB Bulletin for reset classifications.
If the log contains reset errors, perform the Reset test.
6. Place a dispatch call.
7. Look for, and record, any reset errors.
If the unit attempts to reset, perform the Reset test.
8. Place an interconnect call.
9. Look for and record any reset errors.
If the unit attempts to reset, perform the Reset test.
NOTE: If the customer agrees, set the Auto Lock feature. This feature helps detect reset
conditions.