Installation
Preparing for Installation
2-2 MC3000 Digital Deskset Operator and Installation Manual
(6880309L15-A)
Preparing for Installation
Equipment
High impedance audio multi-meter with a range of 80mV
RMS
to 4 V
RMS
, capable of
measuring 1000 Hz
#1 Phillips screwdriver
1/8-inch flat-blade screwdriver
Optionally, an RF service monitor or tone generator
Documentation and Software
MC3000 deskset schematics—in Chapter 4
MC3000 deskset digital radio function buttons cross-referenced to the four radio
types—in Chapter 3
Deskset/s installation plan—specific to the location
Labeling software
Safety Considerations
Cable Installation
Wiring should conform to Article 800 of the National Electrical Code. Ensure you use
listed communication wiring and cabling suitable and specific to the interconnection of
other equipment.
Electrostatic Discharge (ESD) Protection
The deskset has ESD protection circuitry to provide protection from ESD, power and
telephone line surges. The circuitry shunts the transient currents to earth ground.