Troubleshooting Flow Chart for Tx VCO 1-13
5.1 Troubleshooting Flow Chart for Tx VCO (Sheet 2 of 2)
Yes
Vbe ~ 0.7 VDC for Q0200?
Check biasing components
R0207,R0209,L0204,L0206,L0208,
R0213,R0215 & Q0200 for short or
open; then replace Q0200 if needed
No
Yes
Check components from R0200 to
C0233 for shorts and open
Transmit VCO Not locked at correct frequency
Voltage at R0200 between 1.5-10.5 VDC?
No
Check RFIC troubleshooting flow
chart
No
Yes
Check components from R0200 to C0233 for
shorts and open
END