1-14 Troubleshooting Flow Chart for Tx VCO
5.1 Troubleshooting Flow Chart for Tx VCO (Sheet 2 of 2) 
Yes
Vbe ~ 0.73 VDC for Q0200?
Check biasing components 
R0207,R0209,L0204,L0206,L0208, 
R0215,R0213 & Q0200 for short or 
open; then replace Q0200 if needed
No
Yes
Check components from R0200 to 
C0233 for shorts and open
Transmit VCO Not locked at correct frequency
DC voltage at R0200 between 1.5-10.5V?
No
Check RFIC troubleshooting flow 
chart
No
Yes
Check components from R0200 to C0233 for 
shorts and open
END