1-2 Troubleshooting Flow Chart for Receiver
1.1 Troubleshooting Flow Chart for Receiver (Sheet 2 of 3)
A
With a DMM probe R0505   
0.9<V<1.1
No
Yes
Check circuitry around 
U0500 and the entire 
shielded block for shorts 
and opens before replacing 
the part 
With a high impedance probe 
measure the RF level @ 73.35 
MHz @ E0000 
> -38.5 dBm 
No
Yes
With a high impedance probe 
measure the RF level @ 73.35 
MHz @ C0500 
> -49 dBm 
No
Yes
Check circuitry around 
FL0500 and the entire 
shielded block for shorts 
and opens before replacing 
the part 
With a high impedance probe (make sure to use x10 at-
tenuator to prevent overload (20 dB of attenuation)) meas-
ure the RF level @ 561.85 MHz @ C0449. 
> 16 dBm 
No
Yes
Check circuitry from C0468 till 
C0448 for opens and shorts.  (Pin 1 
on Q0405 should have approx. 
8.5V and pin 3 should have approx. 
3.2 v).
With a high impedance probe 
measure the RF level @ 488.5 
MHz @ C0457 
> -38 dBm 
No
Yes
With a high impedance probe 
measure the RF level @ 488.5
MHz at the intersection of 
C0424, C0425, and C0456 
> -38 dBm 
No
Yes
B
With a high impedance  
Probe, probe at 
TP0010M2 @ 146.7 MHz 
Check circuitry around 
T0400, D0404, and
T0401 for opens and 
shorts
Check for opens and 
shorts from L0416 till 
C0457
With a high impedance probe 
measure the RF level @ 
561.85 MHz @ C0468 
> 8 dBm 
No
Yes
Refer to the VCO section 
>-10 dBm 
No
Yes
Refer to Audio Trouble-
shooting chart 
Refer to RFIC