Moxa E Series Managed Ethernet Switch Featured Functions
3-49
Login Authentication
Moxa switches provide two different user login options: Terminal Access Controller Access-Control System Plus
(TACACS+) and Remote Authentication Dial In User Service (RADIUS). The TACACS+ and RADIUS mechanism
is a centralized “AAA” (Authentication, Authorization and Accounting) system for connecting to network
services. The fundamental purpose of both TACACS+ and RADIUS is to provide an efficient and secure
mechanism for user account management.
Setting Description Factory Default
Authentication Protocol
Authentication protocol selection TACACS+
Server IP/Name Set IP address of an external TACACS+/RADIUS server as the
authentication database
None
TCP/UDP Port Set communication port of an external TACACS+/RADIUS
server as the authentication database
TACACS+: 49
RADIUS: 1812
Shared Key Set specific characters for server authentication verification None
Authentication Type Authentication mechanism selection. The ASCII, PAP, CHAP,
MSCHAP are for TACACS+, and the EAP-MD5 is for RADIUS.
ASCII for TACACS+
Timeout (sec) The timeout period to wait for a server response TACACS+: 30
RADIUS: 5