3
RTS/CTS RS-422 Handshaking Signals
The TCC-100 series supports RS-422 handshaking signals. The RTS and CTS
signals help solve the RS-422 signal handshaking problem and reduce data
transmission errors.
Built-in RS-485 ADDC™ Intelligence
ADDC(Automatic Data Direction Control) is a Moxa technology that uses
a clever hardware solution to manage RS-485s data flow control problem.
ADDC™ is a hardware data flow solution that automatically senses and
controls data direction, making the handshaking signal method
unnecessary.
Isolation
Moxas electrical isolation technology uses two photo couplers to create a
gap in each electrical signal. One photo coupler transforms the electrical
signal into a light signal, which is transmitted across a small gap, and then
the other photo coupler transforms the light back into an electrical signal. In
this way, the two electrical circuits are completely isolated from each other,
limiting the damage that could otherwise be caused by ground loops in the
electrical signal.
Reverse Power Protection
The Reverse Power Protection feature provides extra protection against
accidentally connecting the power cables to the wrong terminal. The
converter is designed to automatically detect which power wire is positive
and which is negative, and then adjust the power supply accordingly.
DIP Switch Selectable Terminator
For many products of this type, the termination resistor is set by a jumper
located inside the products casing, so that the user must open the casing to
disable or change the resistors strength. Moxa offers a better solution. The
TCC-100 series’ terminator is configured with a DIP switch located on the
outside of the converters casing.
Auto Baudrate Detection
The TCC-100 series incorporates a method for automatically detecting the
serial signals baudrate by hardware. This is an extremely convenient
feature for the user. Even if a devices baudrate changes, the signal will still
be transmitted through the RS-232 to RS-422/485 converter without any
problem.
www.ipc2u.ru
www.moxa.pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies TCC-100 Series and is the answer not in the manual?

Moxa Technologies TCC-100 Series Specifications

General IconGeneral
BrandMoxa Technologies
ModelTCC-100 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals