Maximum charging current:
To configure total charging
current for solar and utility
chargers.
(Max. charging current =
utility charging current +
solar charging current)
3KW model setting range is from
10A to 120A and increment of
each click is 10A.
5KW model setting range is from
10A to 140A and increment of
each click is 10A.
If “User-Defined” is selected,
battery charge voltage and low
DC cut-off voltage can be set up
in program 26, 27 and 29.
Auto restart when overload
occurs
Restart disable (default)
Auto restart when over
temperature occurs
Restart disable (default)
If selected and utility is
available, inverter will work in
line mode. Once utility
frequency is unstable, inverter
will work in bypass mode if
bypass function is not forbidden
in program 23.
If selected, inverter will work in
line mode when utility is
available.