16
ECO Mode
If selected and bypass is not
forbidden in program 23,
inverter will work in ECO mode
when utility is available.
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02 for
utility charger.
2A
10A
20A
30A (default)
40A
50A
60A
12
Setting voltage point back
to utility source when
selecting “SBU” (SBU
priority) or “SUB” (Solar
first) in program 01
3KW default setting: 23.0V
5KW default setting: 46.0V
3KW model setting range is from 22.0V to 28.5V and increment of
each click is 0.5V.
5KW model setting range is from 44.0V to 57.0V and increment of
each click is 1.0V.
13
Setting voltage point back
to battery mode when
selecting “SBU” (SBU
priority) or “SUB” (Solar
first) in program 01
3KW model: The setting range is from 24.0V to 32.0V and
increment of each click is 0.5V.
Battery fully charged
27.0V (default)