Solar energy provides power to the
loads as first priority.
Overload bypass:
When enabled, the unit will
transfer to line mode if
overload occurs in battery
mode.
Auto restart when overload
occurs
Restart disable
(default)
Auto restart when over
temperature occurs
Restart disable
(default)
Solar or battery energy feed to
grid configuration
Solar or battery energy feed to grid
disable.
Solar or battery energy feed to grid
enable.
Charger source priority:
To configure charger source
priority
If this inverter/charger is working in Line, Standby or Fault
mode, charger source can be programmed as below:
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Solar and Utility
(default)
Solar energy and utility will charge
battery at the same time.
Solar energy will be the only charger
source no matter utility is available
or not.
If this inverter/charger is working in Battery mode or Power
saving mode, only solar energy can charge battery. Solar
energy will charge battery if it's available and sufficient.
Maximum charging current:
To configure total charging
current for solar and utility
chargers.
(Max. charging current = utility
charging current + solar
charging current)
For 1KW~4KW models, setting
range is from 10A to 140A.
For 5KW model, setting range is
from 10A to 180A.
Increment of each click is 10A.