Floating charging voltage
24V model default setting: 27.0V
48V model default setting: 54.0V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 12.0V to 15.3V for 12Vdc model,
24.0V to 30.6V for 24Vdc model and 48.0V to 58.4V for 48Vdc
model. Only for 2.4KW model, setting range is from 24.0V to
29.2V. Increment of each click is 0.1V.
19
Low DC cut off battery voltage
setting
12V model default setting: 10.2V
24V model default setting: 20.4V
48V model default setting: 40.8V
If self-defined is selected in program 14, this program can be
set up. Setting range is from 10.2V to 12.0V for 12Vdc model,
20.4V to 24V for 24Vdc model and 40.8V to 48.0V for 48Vdc
model. Only for 2.4KW model, setting range is from 20.0V to
24V. Increment of each click is 0.1V. Low DC cut-off voltage
will be fixed to setting value no matter what percentage of
load is connected.
20
Battery stop discharging
voltage when grid is available
Available options for 12V models:
11.0V
11.3V
11.5V (default)
11.8V
12.0V
12.3V