16
50A (default)
60A (Only for 4K/5K models)
70A (Only for 4K/5K models)
80A (Only for 4K/5K models)
90A (Only for 4K/5K models)
100A (Only for 4K/5K models)
110A (Only for 4K/5K models)
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be within
170-280VAC.
04
Power saving mode
enable/disable
Saving mode disable (default)
If disabled, no matter connected
load is low or high, the on/off
status of inverter output will not be
effected.
Saving mode enable
If enabled, the output of inverter
will be off when connected load is
pretty low or not detected.
05
Battery type
AGM (default)
Flooded
User-Defined
If User-Defined is selected,
battery charge voltage and low DC
cut-off voltage can be set up in
program 26, 27 and 29.
06
Auto restart when overload
occurs
Restart disable
(default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable
(default)
Restart enable
09
Output frequency
50Hz (default)
60Hz