EasyManua.ls Logo

MPP Solar PIP-HS - Page 19

MPP Solar PIP-HS
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02 for
utility charger.
Available options in 1K model:
10A
20A (default)
Available options in 2K/3K model:
20A
30A (default)
Available options in 4K/5K model:
2A
10A
20A
30A (default)
40A
50A
60A
12
Setting voltage point back
to utility source when
selecting SBU priority or
Solar first in program 01.
Available options in 1K model:
11.0V
11.3V
11.5V (default)
11.8V
12.0V
12.3V
12.5V
12.8V
Available options in 2K/3K model:
22.0V
22.5V
23.0V (default)
23.5V