5.3 Setting Parameter and Default Value
Recommended and default parameter settings are listed below.
Parameter
Battery
type
Absorp.
Stage
Float
Stage
Equalize
Stage
Equlize
Activation
Absorp.
Time
Equalize
Time
Equalize
Timeout
Equalize
Interval
Unit - Volt Volt Volt En/Disable Minutes Minutes Minutes Days
Default AGM 14.10 13.50 14.60 Disable 150 60 120 30
Option Flooded 14.60 13.50 14.60 Disable 150 60 120 30