16
Program
Description
Options
14
Equalization
activated
immediately
Disable (Default)
If equalization function is
enabled in program 08, this
program can be set up.
If Enable” is selected in this
program, it’s to activate
battery equalization
immediately and LCD main
page will shows .
If “Disable” is selected, it will
cancel equalization function
until next activated
equalization time arrives
based on program 13
setting. At this time,
will not be shown in LCD
main page.
Enable
4.5 Reference Code
Type
Code
Event
Fault
01
Over charge current
02
Over temperature
03
Battery voltage is too low
04
Battery voltage is high
05
PV is high loss
06
Battery temperature is too low
07
Battery temperature is too high
Warning
20
PV is low loss
21
Output derating caused from high PV voltage
22
Output derating caused from high temperature
23
Low alarm for battery temperature

Questions and Answers: