27
Protections
Solar high voltage disconnect
Solar high voltage reconnect
Battery high voltage disconnect
Battery high voltage reconnect
High temperature disconnect
High temperature reconnect
Table 2 Battery Charging
MODEL
MPPT 3K
Charging Algorithm
3-Step
Charging stages
Bulk, Absorption, Float
Temperature compensation
coefficient
-5 mV / °C / cell (25 °C ref.)
Temperature compensation range
25 °C to +50 °C
Temperature compensated set
points
Absorption, Float
Charging Set points
Absorption Stage
Float Stage
Flooded Battery
14.6V / 29.2V / 58.4V
13.5V / 27V / 54V
AGM/Gel Battery (Default)
14.1V / 28.2V / 56.4V
13.5V / 27V / 54V
Over-charging voltage
15V / 30V / 60V
Over-charging comeback voltage
14.5V / 29V / 58V
Battery defect voltage
8.5V / 17V / 34V
Battery defect comeback voltage
9V / 18V / 36V
Charging Curve