40
Number Name Settings Notes
0530
Adaptive
Intelligent
Recovery
1 - Adaptive Intelligent Recovery control is
activated (system starts early so set point is
reached by start of program period).
0 - Conventional Recovery (system starts
recovery at programmed time)
0540
Number of
Periods
2 - two periods available (Wake and Sleep)
4 - four periods available (Wake, Leave, Return
and Sleep)
Only shown if schedule
is enabled. Schedule will
default if changed
0580
Minimum
Compressor
O Time
5 - ve-minute compressor off-time setting
(factory setting)
0,2,3,4 - other compressor o-time settings